Add to Cart
DJ-239/140 series Standard type air cooler DJ type cooling fan is mainly applied to -25℃ or less frozen library
DJ condole type air cooler technology parameters | ||||||||||||
Model | Refrigerating capacity | Nominal area | Volume | Inlet/Outlet tube of refrigerant | Eletrothermal defrosting | Parameters of fan | ||||||
Defrosting power of fins | Power of defrosting pan | Quantity | Diameter of fan | Voltage | Power | Air Volume | Range | |||||
W | ㎡ | L | mm | W | W | N | mm | V | W | m3/h | m | |
DJ-1.7/10 | 1700 | 10 | 2.7 | Ф12/Ф19 | 2400 | 1200 | 2 | 300 | 380/220 | 2*75 | 3126 | 8 |
DJ-3.4/20 | 3400 | 20 | 5.8 | Ф16/Ф22 | 2400 | 1200 | 2 | 400 | 380/220 | 2*180 | 6800 | 10 |
DJ-5.1/30 | 5100 | 30 | 7.6 | Ф16/Ф22 | 3000 | 1500 | 2 | 400 | 380/220 | 2*180 | 6800 | 10 |
DJ-8.9/55 | 8900 | 55 | 13.5 | Ф19/Ф40 | 6000 | 1500 | 2 | 500 | 380 | 2*414 | 12000 | 15 |
DJ-14.3/85 | 14300 | 85 | 19.6 | Ф25/Ф40 | 8000 | 4000 | 3 | 500 | 380 | 3*414 | 18000 | 15 |
DJ-17.9/105 | 17900 | 105 | 22.7 | Ф25/Ф48 | 9600 | 4800 | 4 | 500 | 380 | 4*414 | 24000 | 15 |
DJ-23.9/140 | 23900 | 140 | 32.2 | Ф25/Ф50 | 12000 | 4800 | 4 | 500 | 380 | 4*414 | 24000 | 15 |
DJ-28.9/170 | 28900 | 170 | 41.9 | Ф28/Ф54 | 16800 | 4800 | 4 | 550 | 380 | 4*600 | 32000 | 15 |
DJ-35.8/210 | 35800 | 210 | 51.6 | Ф28/Ф54 | 21600 | 4800 | 4 | 600 | 380 | 4*780 | 40000 | 15 |
Remark:When Tr=-18℃ and Δt=7℃,R134a energy should multiply correction factor f,that is QoR134a=QoR22Xf. |
Product Features:
D series air cooler is a complete library of cooling cooling equipment freon refrigeration unit used;by the use of temperature to sub-divided into DL,DD,DJ three series,can be separately applied to different storage temperature ,DL type air cooler mainly applied to the preservation of about 0℃,DD type air cooler is mainly applied to the refrigerator of -18℃,DJ type cooling fan is mainly applied to -25℃ or less frozen library.